DriveErase organizes sanitization into Pre-processing, Execution, and Post-processing. Separating these stages allows you to examine a device before erasure, choose the method used to remove its data, and optionally evaluate its condition afterward.
The settings apply to each selected device individually. If a job contains several drives, they can use different methods and diagnostic options depending on their technology and intended future use.
Stage 1: Pre-processing
Pre-processing takes place before destructive sanitization begins. DriveErase can request available SMART information to identify health conditions that might affect the drive’s reliability or ability to complete erasure.
The SMART Health Check option enables this assessment. Fail Job on SMART Failure determines whether the device should stop when the assessment fails or produces an unacceptable result.
A failed SMART check does not always mean that the drive cannot be erased. Some controllers do not expose the required diagnostic commands, and some damaged drives remain accessible for ordinary writes. If you are processing a failing drive for disposal, you may choose to continue despite the SMART failure, provided that the resulting sanitization method and evidence are acceptable.
For a drive that is intended for continued use, recording a successful initial health assessment can be useful when comparing its condition before and after erasure.
Stage 2: Execution
Execution is the destructive stage in which DriveErase performs the configured sanitization method.
With Overwrite Based, the application writes the selected pattern sequence across the accessible logical address range. This is generally suitable for magnetic hard drives and is also the available approach for USB-attached storage.
With Firmware Based, the storage device performs a supported firmware operation. This is available in Pro and higher editions for compatible directly attached SATA SSDs, NVMe devices, and SAS SSDs.
Firmware + Fallback first attempts the preferred firmware operation and can proceed with a selected overwrite method if the firmware operation fails. Because the methods have different coverage, the final result must identify which one actually completed.
Stage 3: Post-processing
Post-processing takes place after the erasure stage and is optional. Pro, Enterprise, and Audit can perform SMART self-tests, full media read scans, sampled write verification, performance measurements, and combined health assessments.
For example, a hard drive can complete a successful overwrite but still contain unreliable sectors or display abnormal read latency. A post-erasure test can reveal these problems before the drive is reused.
Conversely, a healthy drive may still have an unsuccessful sanitization result. Health and erasure are separate assessments and should not be combined into one overall claim.
Completing the job
DriveErase records the outcome of the configured stages for each device. When the Privileged Execution Environment finishes, review the results and follow the displayed instructions for returning to Windows.
If reporting is available in your edition, export the required information and associate it with the correct physical device. A job containing multiple drives can have different results, so each target must be examined individually before it is returned to service or released from your control.