Sampled Write-Verify Test

Sampled Write-Verify Test checks whether selected logical regions of a storage device can be written and immediately read back correctly after sanitization. It is available in Pro, Enterprise, and Audit and is intended for situations where the drive’s future usability matters.

Unlike a media read scan, this test is destructive because it writes new data to the device. It should therefore be used only after sanitization or on storage whose previous contents can safely be discarded.

How the test is performed

DriveErase selects representative sample regions near the beginning, middle, and end of the accessible logical range. Each region can include up to 1 GiB of storage, depending on the device’s capacity.

The assessment writes an all-zero test pattern to the selected regions and immediately reads the data back. The returned contents are compared with the expected zero pattern to identify write errors, read failures, or mismatches.

This process examines whether the sampled locations respond correctly to ordinary write and read operations. DriveErase records the detected problems and includes the available results in the post-erasure health assessment.

Why the test is useful

A drive may be able to read existing information but fail when new data is written. For example, a deteriorating SSD might return errors during writes, while a magnetic HDD might have sectors that read successfully but cannot reliably accept new information.

Sampled Write-Verify Test can help identify these conditions without requiring a complete write of the entire device.

For a computer-repair business refurbishing used drives, the test can provide additional evidence that representative storage regions remain usable. An IT department may also include it when assessing drives for redeployment to less demanding systems.

Understanding the limitations

The test examines selected regions rather than every logical block. Successful samples therefore do not prove that all other locations can be written.

The immediate readback can also be influenced by caching in the device or controller. Because DriveErase does not power-cycle the drive between writing and reading, the test does not establish that the data would necessarily survive an unexpected loss of power.

These limitations do not make the test unhelpful, but they define what its result demonstrates.

After the assessment

A successful result provides evidence that the tested regions accepted the zero writes and returned the expected values during immediate verification.

If write errors or mismatches are reported, consider using a more comprehensive assessment or retiring the drive. For a storage device intended for important workloads, a failed sampled write test is a significant reason not to return it to service without further investigation.

The test result does not change the original sanitization classification. It is a separate assessment of the device’s condition after erasure.