DriveErase allows each selected device to have its own sanitization configuration. This means a single job can process different storage technologies using different methods, provided that each selection is supported by the active edition and the hardware.
The settings are grouped into Pre-processing, Execution, and Post-processing. They correspond to the three stages of the sanitization workflow and determine which health checks and erasure operations will be performed.
Pre-processing
The SMART Health Check option controls whether DriveErase attempts to examine the drive’s available SMART diagnostic information before erasure. SMART can identify certain health problems, although its availability depends on the storage device and controller.
The Fail Job on SMART Failure option determines whether the affected device should stop when the pre-erasure assessment fails or reports an unacceptable condition. When this option is disabled, DriveErase can record the problem and continue attempting sanitization.
Both settings are available in all editions. Keeping the SMART assessment enabled is generally useful, but an unavailable SMART response should be interpreted in the context of the device and connection.
Execution
The Sanitization Approach determines whether DriveErase uses logical overwriting, a supported device-firmware operation, or firmware sanitization with overwrite fallback.
With Overwrite Based, select the required profile under Overwrite Method. Available choices include NIST SP 800-88 Clear, IEEE 2883-2022 Clear, and the supported historical and random overwrite methods.
With Firmware Based, DriveErase uses the applicable firmware method for a compatible directly attached SSD. This can involve SATA/ATA SSD Secure Erase, NVMe Format NVM Secure Erase, or SCSI Sanitize Block Erase, depending on the device type.
With Firmware + Fallback, the firmware method is attempted first. If it cannot complete, the configured overwrite profile can be attempted instead. The final result will reflect which method actually completed.
Standard supports only Overwrite Based. Firmware approaches require Pro, Enterprise, or Audit.
The Potential Compliance field displays the sanitization outcome that may be possible with the selected combination of device and method. It is informational and should not be confused with the actual result recorded after execution.
Post-processing
The Disk Health Check setting determines whether DriveErase performs additional diagnostics after erasure.
Pro and higher editions provide SMART Quick Health Check, SMART Short Self-Test, SMART Extended Self-Test, Full Media Read Scan, Full Media Read Scan + Performance Analysis, Sampled Write-Verify Test, Read Performance Benchmark, Extended Media Validation, and Full Health Assessment.
The None option disables the post-erasure assessment and is the only post-processing choice available in Standard.
For a drive that will be reused, a post-erasure assessment can provide useful information about its condition. If the device is being destroyed after sanitization, a lengthy health test may offer little practical benefit.
Reviewing several devices
When configuring multiple targets, check the settings for each one rather than assuming they are identical. An overwrite method appropriate for a SATA HDD is not necessarily the preferred choice for an NVMe SSD, and a device connected through USB may not support firmware sanitization at all.
Before starting, confirm the pre-erasure SMART behavior, selected sanitization approach, overwrite or firmware method, fallback profile where applicable, potential compliance, and post-erasure health assessment. This final review is particularly important when processing several drives with different technologies in one job.